Chang Yih inverter manufacturer

3 Phase 1HP~40HP

  • Current Vector Control Inverter 3 Phase 1HP~40HP
  • V/F & Sensorless Vector Control& Current
    Vector Control & Zero Servo
  • Support IPM& SPM motor
  • 200% torque performance at extreme low speed (0.5Hz), Overload 150% 60S
  • Support encoder feeback card
  • PID Feeback Control & Water Pump PID
  • Energy Saving & Automatic voltage regulation
  • Supports 2 independent induction motor control
  • Parameter sets output frequency 0.01-400Hz
  • Zero speed holding fun & Sleep/Revival Function
  • 6-set speed control & 15-set process control
  • Low noise, Carrier Frequency 1-15K
  • Product Description
  • Product Feature
  • Product Specification
Current Vector Control Inverter 3 Phase 1HP~40HP

230 Series:

Model Number
CY-S200- ### -23
100 101 103 104 105 106 107 108 109 110
Motor Output(KW) 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5
Motor Output(HP) 0.5 1 2 3 5 7.5 10 15 20 25
Rated Frequency(Hz) 0.01~400Hz
Rated Frequency(A) 3.1 4 7.1 10 17.5 22 32 45 62 71
Rated Voltage 3 Phase 220VAC±10%
Motor Current(A) 2.2 3.4 6.1 8.7 13.5 20.1 25.1 36.7 50.3 62.9
Motor Frequency(Hz) 60.00
Slipping Frequency(Hz) 3.00
Carrier Frequency(Hz) 1~15K
Cooling Method Forced Fan

440 Series:

Model Number
CY-S200- ### -43
200 201 202 203 204 206 207 208 209 210 211 212
Motor Output(KW) 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30
Motor Output(HP) 0.5 1 2 3 5 7.5 10 15 20 25 30 40
Rated Frequency(Hz) 0.01~400Hz
Rated Frequency(A) 2 2.9 3.8 5.7 8.1 11 15.5 22.5 32 40 45 60
Rated Voltage 3 Phase 380/440VAC±10%
Motor Current(A) 0.9 1.6 2.8 4.1 6.8 9.9 12.7 18.9 24.7 31 37.6 48.1
Motor Frequency(Hz) 60.00
Slipping Frequency(Hz) 3.00
Carrier Frequency(Hz) 1~15K
Cooling Method Forced Fan

Current Vector Control Inverter 3 Phase 1HP~40HP
Current Vector Control Inverter 3 Phase 1HP~40HP
Current Vector Control Inverter 3 Phase 1HP~40HP

Applicable motor power Mounting Dimensions External Dimensions Install Aperture(mm) Frame
Model A B H W D    
CY-S200-101-23
CY-S200-102-23
CY-S200-103-23
CY-S200-201-43
CY-S200-202-43
CY-S200-203-43
106.6 175 185 118 154 4 B
CY-S200-104-23
CY-S200-105-23
CY-S200-106-23
CY-S200-204-43
CY-S200-205-43
CY-S200-206-43
CY-S200-207-43
148 235 247 160 175 5 C
CY-S200-107-23
CY-S200-108-23
CY-S200-109-23
CY-S200-208-43
CY-S200-209-43
CY-S200-210-43
CY-S200-211-43
264 385 403.5 300 201.6 10 D
Control Characteristics Control Method SPWM Control (V/F, Sensorless Vector Control, V/F+PG, PMSV, PMSLV)
Torque Characteristics the auto-torque, auto-slip compensation; starting torquecan be 150% at 5.0Hz
Overload ability 150% of rated current for 1 minute
Accel/Decel Time 0.01 ~ 600seconds
V/F Curve Adjustable V/F Curve set up
stall Prevention 20 to 200%, Setting of Rated Current

 

Frequency Setting Keypad Setting by Keypad button (up/down)
External Signal Potentiometer-5KΩ/0.5W, 0 to +10VDC, 4 to 20mA, RS485 interface; Multi-Function Inputs 0 to 5 (7 steps, Jog, up/down)
Operation Setting Keypad Set by RUN, STOP
External Signal M0 to M5 can be combined to offer various modes of operation,RS-485 serial interface (MODBUS).
Multi-Function Input Signal Multi-step selection 1 to 7, Jog, accel/decel inhibit, first to forthaccel/decel switches, counter, PLC operation, external BaseBlock (NC, NO), UP/DOWN key settings, selections, driver reset
Multi-Function Output Indication Inverter operating, frequency reach, non-zero, base block, fault indication, local/remote indication, PLC operation indication, auxiliary motor output, overheat alarm, emergencystop
Analog Output Signal Analog frequency/current signal output
Operation Functions AVR, S-Curve, over-voltage, over-current stall prevention, faultrecords, adjustable carrier frequency, DC braking, momentary power loss restart, auto tuning, frequency limits, parameterLock/Reset, vector control,PID Control, counter, PLC, MODBUS communication, reverse inhibition, abnormal reset, abnormal restart, digital frequency output, sleep/revival function, frequency source selections
Protection Functions over voltage,over current, under voltage, overload, overheating, electronic thermal,ground fault
Cooling Method Forced Fan